產(chǎn)品資料

**供應德國費斯托信號轉換器,FESTO轉換器優(yōu)點(diǎn)介紹

如果您對該產(chǎn)品感興趣的話(huà),可以
產(chǎn)品名稱(chēng): **供應德國費斯托信號轉換器,FESTO轉換器優(yōu)點(diǎn)介紹
產(chǎn)品型號: LFR-1-D-MAXI-A-MPA
產(chǎn)品展商: FESTO
產(chǎn)品文檔: 無(wú)相關(guān)文檔

簡(jiǎn)單介紹

**供應德國費斯托信號轉換器,FESTO轉換器優(yōu)點(diǎn)介紹 ?visualising the signals and parameters, and can thus be used as a remote display for transmitters. The switching outputs can be configured to monitor a threshold value, signal range or signal change. The outputs can be set as PNP or NPN and normally open (NO) or normally closed (NC). Process values can be read out and parameters changed and **供應德國費斯托信號轉換器,FESTO轉換


**供應德國費斯托信號轉換器,FESTO轉換器優(yōu)點(diǎn)介紹  的詳細介紹

**供應德國費斯托信號轉換器,FESTO轉換器優(yōu)點(diǎn)介紹
  上海乾拓貿易有限公司
企業(yè)QQ:
電話(huà);021-69001039
手機;17321017802(微信)
郵箱;17321017802@163.com
地址:上海市嘉定區江橋嘉涌路99弄6號713室
 visualising the signals and parameters, and can thus be used as a remote display for transmitters.
The switching outputs can be configured to monitor a threshold value, signal range or signal change.
The outputs can be set as PNP or NPN and normally open (NO) or normally closed (NC).
Process values can be read out and parameters changed and transmitted to additional devices via the IO-Link® interface.
 Converts analogue signals into digital switching signals  Conversion of analogue signals in IO-Link® 
 Reduction in analogue signals to the control systems 
 inchHg  inchH2O  kgf/cm2  l/min  l/h  scfm  scfh  GPM  mm  inch  V  MA  %
Flexible use  Transmitter signal area scalable (e.g.: 1 … 5 V) 
 Pressure transmitters SPTE, SDE5-NF-V, SPTW  Vacuum generator OVEL with SPTE 
 Flow transmitters SFET-F, SFET-R  Position sensors SDAT, SMAT-8E, SMAT-8M 
Analogue sensor box SRAP  Inductive sensors with analogue output SIEA
Certification RCM compliance mark CE marking (see declaration of conformity)
In accordance with EU EMC Directive Ambient temperature [°C] 0 … +50 Note on materials RoHS compliant
Input signal –2V –2A
Measured variable Voltage Current Signal range [V] 0 … 10 – [mA] – 0 … 20 Sampling interval [ms] 1
Output, general
Accuracy FS [%] 0.5 Repetition accuracy [%] 0.2
Switching output
Switching output 2 x PNP or 2 x NPN, switchable Switching function Freely programmable Switching
 element function N/C or N/O contact, switchable Max. output current [mA] 100 Short circuit protection Yes
Operating voltage range DC [V] 15 … 30 Reverse polarity protection For all electrical connections
Electrical connection, input Function Analogue input, power supply Connection type 2x socket
Connection technology Plug pattern EC Number of pins/wires 4
Electrical connection, output Function Power supply, communication, switching output
Easy operation  Blue display with high-contrast white text and red switchover
 Intuitive menu navigation, as for pressure sensors SPAU and SPAN
Communication interface
Many integrated functions  Min./max. monitoring  PNP/NPN, switchable
 Eco mode  Tamper protection with security code  Filter can be adjusted to smooth the signals 
 The switching points can be easily set via teach-in  Parameters can be easily copied to other devices
Values can be displayed in many units  bar  kPa  MPa  psi  mmHg 
Measured value indicator can be individually configured  Lots of integrated switching functions
Product description Area of application
The signal converter detects analogue current or voltage signals from sensors (transmitters).
 Connection to the higher-level system is provided by 1 or 2 switching outputs
or alternatively by an IO-Link® interface. The signal converter has a display for
Connection type Plug connector Connection technology Plug pattern L1J Number of pins/wires 4
IO-Link® device to IEC 61131-9
Protocol IO-Link®
Protocol version Device V 1.1 Profile Smart sensor profile Function classes Binary data channel
 (BDC) Process data variable (PDV) Identification Diagnostics Teach channel Communication mode COM2
(38.4 kBaud) SIO mode support Yes Port class A Process data width OUT 0 bytes Process data width
 IN 5 bytes Process data content IN 14 bit PDV (measured value InA) 14 bit PDV (measured value InB)
2 bit BDC (measured value monitoring) Minimum cycle time 5 ms Data memory required 0.5 kilobyte
Fast and decentralised signal processing to reduce the load on the control system  Remote visualisation of process values,
the display is detached  Quantity detection, e.g. pressure transmitters, vacuum transmitters, flow transmitters 
 Object detection, e.g. inductive sensors with analogue output, distance sensors
  Position detection, e.g. position sensors for pneumatic cylinders  Auto difference monitoring, e.g. leak test
The signal converter can be used with the following Festo products, for example.

**供應德國費斯托信號轉換器,FESTO轉換器優(yōu)點(diǎn)介紹


Copyright@ 2003-2024  上海乾拓貿易有限公司版權所有     

Copyright@2003-2018 上海乾拓貿易有限公司版權所有 電話(huà):021-39529830/39-8005  021-39529831/29-8002 傳真:021-39529839 

地址:上海嘉定嘉涌路99弄6號713 郵編:201812  易展提供技術(shù)支持  滬ICP備09006758號-20    網(wǎng)站管理入口

         滬ICP備09006758號-20   

滬公網(wǎng)安備 31011402005010號

點(diǎn)擊這里給我發(fā)消息 點(diǎn)擊這里給我發(fā)消息 點(diǎn)擊這里給我發(fā)消息 點(diǎn)擊這里給我發(fā)消息 點(diǎn)擊這里給我發(fā)消息 點(diǎn)擊這里給我發(fā)消息 點(diǎn)擊這里給我發(fā)消息 武川县| 天等县| 清徐县| 鹰潭市| 天门市| 柳林县| 东平县| 西畴县| 吉首市| 宾川县| 蒲江县| 乳山市| 延寿县| 陵川县| 抚宁县| 平定县| 威信县| 永德县| 兴安县| 耒阳市| 平阳县| 河间市| 壤塘县| 蒙城县| 咸阳市| 冀州市| 阆中市| 仁布县| 昔阳县| 高青县| 财经| 道孚县| 元谋县| 德江县| 达孜县| 沈阳市| 唐海县| 图片| 堆龙德庆县| 赣州市| 安平县|